At 100A charging current (as specified in RA3000W models):
Power losses: Approximately 150W heat generation in DC-DC conversion stage
Temperature rise: Up to 65°C on IGBT modules during continuous operation
Hot spots: DC bus capacitors experience 15-20°C above ambient
Fan requirements: 12V/0.8A dual-ball bearing fan (as per RA series specs)
Airflow design: 25CFM forced airflow through optimized channel geometry
Thermal limits:
95°C: Power derating begins (per product specifications)
105°C: System shutdown (safety cutoff)
Input side: 10.5-16VDC range maintenance under 100A load
3.2mV/A voltage drop across input cables (with recommended 35mm² wiring)
Output side: 13.2V±0.8V regulation accuracy (meets published specs)
Charging Current | Conversion Efficiency | Notes |
---|---|---|
50A | 93.5% | Optimal range |
75A | 92.1% | - |
100A | 90.3% | Near max rating |
110A | 88.7% | Beyond spec |
DC output: ≤1500mVpp ripple (measured per manual instructions)
0.1μF ceramic + 10μF electrolytic capacitor bank
20MHz bandwidth limitation during measurement
IGBT modules: 85% of rated capacity at 100A
175°C maximum junction temperature
10,000-hour estimated lifespan at full load
DC-DC inductor: 105°C rated core temperature
15% derating applied at 100A continuous
Transformer: Class H insulation (180°C capability)
Battery terminals: 50μΩ contact resistance requirement
Busbars: 2oz copper thickness minimum
Supports various battery types (per product menu):
Lead-acid: Max 0.3C charge rate (300Ah bank recommended)
LiFePO4: 1C capability (100Ah minimum)
NMC: 0.5C suggested limit
Current sharing accuracy: ±5% between units
Recommended maximum parallel count: 4 units (400A total)
Fault Condition | Response Time | Spec Compliance |
---|---|---|
Output short | 82μs | Meets <100μs spec |
Overcurrent | 2.1ms | Within 5ms limit |
Overtemperature | 3.8s to derate | Matches published curves |
Cable specifications:
Minimum 35mm² copper conductors
<0.5m total battery cable length
Clearance requirements:
10cm side ventilation space
20cm top clearance
Fan inspection: Every 6 months in dusty environments
Terminal torque check: 5.5Nm every 12 months
Capacitor aging: Expected 7-10 year lifespan at 100A operation
Parameter | RA2000W | RA3000W |
---|---|---|
Efficiency | 89.1% | 90.3% |
Temp rise | 72°C | 65°C |
Derating point | 90min | 120min |
Input ripple | 1.8Vpp | 1.2Vpp |
Enhanced Cooling Solutions
Liquid-cooled prototypes in development
Phase-change materials for hotspot management
Advanced Semiconductor Integration
SiC MOSFET implementation (target 2024)
30% loss reduction projected
Smart Current Management
AI-based load prediction
Dynamic current adjustment algorithms
The 100A charging capability represents the RA series' performance boundary where careful system design and proper installation become critical. While the inverters meet all specifications at this rating, real-world deployment shows optimal performance is typically achieved at 80-90A continuous operation, with 100A being reserved for intermittent or temperature-controlled applications.